Hardware I.P.B. 4244 5th August 1998 (SRS)
Department Category Implementation
Hardware Hardware Advisory

Previous IPB

Index of Hardware IPBs

Possible CPU error on boot on FT1400 servers

We have had reports on a handful of systems where two error messages are displayed during boot on the FT1400. These are;-

CPU error 3 on timer
and
Error 810E - CPU failed.

These are caused by a BIOS error, and can be corrected by a re-test of the processor.

To clear the error messages, the Processor re-test option must be set to YES in the BIOS F2 setup under the Server menu.

This will cause a re-test of the installed processor and clear the error flag, unless there is a genuine CPU error, in which case the appropriate error message will be displayed.