Networking I.P.B. 2043 25th October 1990 (SF)
Department Category Implementation
Network Software Mandatory
Previous IPB Next IPB

Installing Sytos Plus for OS/2 1.21 on a VX FT

The following procedure details the method of installing SYTOS PLUS on a VX FT running OS/2 1.21.

  1. Run the install program from the Sytos plus diskette.
  2. Select the directory where the software will be installed.
  3. The device drivers menu will then appear. You must select the ARCHIVE 2150s -ISA driver for any internal tape in the VX FT.

The software will then be copied onto the hard disk.

The install program will then ask whether you want the driver added to CONFIG.SYS, answer YES to this question. You then get the option of creating a Sytos plus group in Presentation manager; it is best to create this group because it makes it easier to run Sytos plus.

Before you reboot the machine you MUST remove a line from the config.sys file that the installation program has added. The line is:

DEVICE=C:\SYPLUS\SYFILES\aspi4os2.sys

This line must be removed because the existing Adaptec disk driver already contains an ASPI driver, therefore this driver is not needed.

WARNING

If you reboot before editing out the driver, the machine will hang and OS/2 will have to be re-installed.

Once this line has been edited out, the FT should be rebooted and Sytos can be used.

N.B. Sytos plus for OS/2 only works on OS/2 version 1.21. If you wish to use Sytos plus on OS/2 1.1, you must boot from DOS 4 and use the DOS version of Sytos plus, as an OS/2 partition is similar in structure to a DOS 4 partition.

----------oOo----------

 