Enhanced Workstation Boot Floppies on LAN
Manager 2.00B
This IPB serves as an update to the Server Environment for OS/2 LAN
Manager 2.0 Installation guide.
When creating an enhanced workstation boot floppy as per section 3b on
page 2/8 of the guide, using release 2.00 or 2.00A of LAN Manager 2 the installation would
run smoothly. However with release 2.00B there has been an extra help file added which now
means that all of the files will no longer fit onto a high density floppy. The solution to
the problem is as follows:
The extra file is called NETH.MSG and is located in the directory
\lanman.dos\netprog . This file is only needed for on line help on LAN Manager NET errors
and so is not really needed by the average user.
The solution is therefore to remove the line
\lanman.dos\netprog\*.msg
and replace it with the lines
\lanman.dos\netprog\oso001.msg
\lanman.dos\netprog\net.msg
All of the files will now fit onto one high density floppy as before.
----------oOo---------- |